CT has much higher image resolution than radiography-based techniques like mammography, which could be a boon in trying to detect the small structures that can be signs of early-stage breast cancer. But CT's radiation dose is typically much higher than that of mammography, which could be a major issue due to the need to conduct repeat studies if used in a screening environment.
No dedicated breast CT system is on the market as of yet, but groups working to develop commercial systems include the University of California, Davis, and the University of Rochester in New York, which has licensed its technology to Koning of West Henrietta, NY.
In a session on new technologies on Saturday afternoon, Sabrina Vollmar from the Institute of Medical Physics at Friedrich-Alexander-University in Erlangen-Nuremberg, Germany, discussed the university's approach to breast CT. Working as part of a group that includes CT pioneer Willi Kalender, Ph.D., university researchers have built a prototype unit in which a woman lies prone on the patient table, with the breast hanging pendant-style through a hole in the table. The system is based on conebeam CT geometry, and does not use breast compression, unlike conventional mammography.
The system features a 20 x 20-cm field-of-view, and acquires 360 projection images per gantry rotation. The system has a pixel size of 200 microns. This compares to two projections typically used in mammography, with full-field digital mammography systems typically having pixel sizes of 100 microns, Vollmar said.
To study the breast CT system's imaging characteristics in comparison to mammography, the group designed two phantoms, one for use with each modality. The phantoms were of different sizes to simulate the size of the breast when imaged with the different techniques, with the breast CT phantom measuring 10 x 10 cm while the second one was 5 x 14 cm. The phantoms included structures simulating both soft-tissue tumors and microcalcifications.
To measure radiation dose for each modality, the group used the Monte Carlo method, and measured 3D dose distribution across the entire phantom. They also measured the integral dose for both phantoms. To assess image quality the group calculated contrast-to-noise ratio (CNR) and dose-weighted contrast-to-noise ratio (CNRD).
The group imaged the phantoms at energies ranging from 15 keV to 100 keV, with the group finding that the best energy ranges for breast CT in terms of CNR was 28 keV, and for CNRD at 34 keV. Dose increased at higher energies used, Vollmar said.
Both systems delivered comparable radiation dose to the phantoms. The breast CT system delivered 4.5 mGy per study, versus 4.8 mGy for mammography when both projections from a standard two-projection study were added together.
As for image quality, Vollmar said that both systems performed comparably in the detection of microcalcifications. But for tumors, the breast CT unit had twice the image quality of mammography -- the system was able to detect "tumors" in the phantom as small as 2 mm, versus 4 mm for the mammography system.
"Breast CT offers the potential for the detection of small soft-tissue lesions, makes compression of the breast obsolete, and offers image quality at least equivalent to mammography, without an increase of dose level," Vollmar said.
How soon could the group move from a prototype system to a unit able to scan patients? In remarks after Vollmar's presentation, Kalender estimated that such a system could be a couple years away.
By Brian Casey
AuntMinnie.com staff writer
March 11, 2007
Related Reading
Koning introduces CT for breast imaging, November 26, 2006
Imaging start-up to install conebeam CT breast imaging prototype, May 1, 2006
Breast CT developers aim to 'revolutionize' mammography, December 20, 2005
Researchers make inroads with breast CT, gear up for clinical test, July 25, 2005
UC Davis tests breast CT, May 11, 2005
Copyright © 2007 AuntMinnie.com